Analysis Of Completeness Of Blood Vacuume Tube Filling At A Clinical Laboratory Attached To Tertiary Care Center, A Cross Sectional Study

Analysis Of Completeness Of Blood Vacuume Tube Filling At A Clinical Laboratory

Authors

  • Dr. Chinka Patel 3rd Year Resident Doctor,Department Of Biochemistry, Government Medical College, Surat, Gujarat, 395001
  • Dr. Puneet Saxena Associate Professor,Department Of Biochemistry, Government Medical College, Surat, Gujarat, 395001
  • Dr. Neelam Karbhari Tutor, Department Of Biochemistry, Government Medical College, Surat, Gujarat, 395001

DOI:

https://doi.org/10.70284/njirm.v13i3.3515

Keywords:

Volume incompleteness, Vacuum tube, OPD, Non-OPD

Abstract

Background: Overfilled and under filled tube are most important cause of pre-analytical error and failure to complete requested examination in sample. The study was performed to analyse relationship between time of receiving of sample, location of sample, type of vacuum tube, method of collection, total volume required in a patient and volume incompleteness. Material And Methods: The study involved collection and patient samples data, i.e. receiving time of sample, place of collection, type of vacuum tube, blood collection method, total volume required in a patient, measurement of volume before processing. Average incompleteness of vacuum tube was calculated and average relationship between incompleteness and these parameters done.Result: Average incompleteness in OPD samples is better than Non-OPD samples. Average incompleteness is better during 9 am to 12 am than early morning hours. Incompleteness with relation to vacuum tube type is in general Plain > (EDTA/Fluoride) > Citrate. Average incompleteness better in sample collected with vacuum tube needle with holder than use of syringe. Average incompleteness increases as total volume required in a patient increases. Conclusion: Dedicated phlebotomist and use of vacuum tube needle with holder is required to bring overall improvement in completeness of blood collection. [Patel C Natl J Integr Res Med, 2022; 13(3): 10-14, Published on Dated: 10/05/2022]

Downloads

Published

2022-12-09

How to Cite

Dr. Chinka Patel, Dr. Puneet Saxena, & Dr. Neelam Karbhari. (2022). Analysis Of Completeness Of Blood Vacuume Tube Filling At A Clinical Laboratory Attached To Tertiary Care Center, A Cross Sectional Study: Analysis Of Completeness Of Blood Vacuume Tube Filling At A Clinical Laboratory. National Journal of Integrated Research in Medicine, 13(3), 10–14. https://doi.org/10.70284/njirm.v13i3.3515

Issue

Section

Original Articles